Inert-Gas Thermocouple with Sheath Tube Connection
Inert-gas thermocouples are suitable for atmospheric processes with a slight vacuum of up to 60 mbar and can withstand overpressure of up to 2 bar.

Inert-gas thermocouples are suitable for atmospheric processes with a slight vacuum of up to 60 mbar and can withstand overpressure of up to 2 bar.

For use in atmospheres containing inert gas, protective gas, or carbonization, or in air atmospheres with a negative pressure of 30 mbar up to a brief period of positive pressure of 2 bar
The specification is structured as follows:
| 8 | - | 01 | XX | TT | - | LLLL | PPP | A |
| 8 | Thermocouple | ||||||||||
| 01 | Gas-tight to 30 mbar and pressure-resistant up to 2 bar | ||||||||||
| XX | Number of installed thermocouples + empty test tube | ||||||||||
| TT | Thermocouple Type
| ||||||||||
| LLLL | Nominal length in mm from 0400 to 1600 | ||||||||||
| PPP | Process connection
| ||||||||||
| A | Optionally available with a calibration certificate in accordance with the current AMS 2750 / CQI-9 standard |
| 8 | - | 01 | 03 | 01 | - | 0700 | SR22 |
Inert-gas thermocouple with a Ø22 x 150 mm holder tube as a process connection, 2 Type S thermocouples, and a nominal length of 700 mm


Download the free eDrawings Viewer program to view our files on various devices without needing CAD software.
We’d be happy to receive your inquiry. Please feel free to use the form below. You can use the search function to find the right product in our database by part number, specifications, or serial number. Alternatively, you can quickly customize your desired product using the configurator.