thermo-control Körtvélyessy GmbH

Since 1983, thermo-control Körtvélyessy GmbH has been manufacturing Drift-free platinum-rhodium and platinum thermocouples and high-precision oxygen probes for industrial excellence. Discover our Product Portfolio and stay up to date!

As a lean organization, we achieve delivery times that often surprise and delight our customers. We meet our standard delivery time of 2–3 days for custom-made products 95% of the time. Put us to the test and send your Inquiry!

Our Main Products

thermo-control S-type thermocouple with high process reliability

Thermocouples

  • Guaranteed high process reliability
  • Up to a 4-year warranty on the S-Type
  • Separate empty tube for test measurements
  • Complies with the AMS 2750 secondary standard
Learn More
thermo-control ceramic oxygen probes for the 480–1300°C range

Oxygen probes

  • High-precision reproduction of the Nernst voltage
  • All-ceramic design
  • Temperature range: 480 °C – 1300 °C
  • No external reference air supply required
Learn More
thermo-control Calibration Thermocouple with AMS-2750 Certification

Calibration Thermocouples

  • Compatible with all thermo-control thermocouples
  • Standard lengths: 400 mm – 1500 mm
  • Calibration certificate in accordance with AMS-2750 available
  • Recommended recalibration interval: 10 years
Learn More


Drift-Free Thermocouples

thermo-control Körtvélyessy GmbH develops and manufactures high-quality PtRh – Pt thermocouples. Our patented design ensures exceptional precision, durability, and reliability. By using thermowires of different diameters, temperature-induced drift is eliminated, resulting in a thermocouple that never drifts.

Plot of stress-strain curves with the same thermowire diameters
Specifications
ΔT NewΔT Year 1ΔT Year 2ΔT Year 3
Positive wire (PtRh10%)+0.0K+1.0K+1.5K+2.0K
Negative Lead (Pt)+0.0K+5.0K+8.0K+10.0K
ΔT = Drift0.0K-4.0K-6.5K-8.0K

Result of a drift measurement at 1240°C using a Type S thermocouple (2 wires, each Ø 0.5 mm)

Plots of stress-strain curves for different thermowire diameters
ΔT NewΔT Year 1ΔT Year 2ΔT Year 3
Positive wire (PtRh10%)+0.0K+1.0K+1.5K+2.0K
Negative Lead (Pt)+0.0K+1.0K+1.5K+2.0K
ΔT = Drift0.0K0.0K0.0K0.0K

Result of a drift measurement at 1240°C using a Type S thermocouple (0.35 mm diameter positive wire and 0.5 mm diameter negative wire)


Your inquiry

Search our database

Create a position

Specifications
PositionQuantityMaterial

Positions Created

No products selected

Your contact information


By submitting this form, I consent to the temporary storage and use of the data provided for the purpose of contacting me. For details, see our Privacy Policy.

Select this option if you would like to receive a copy of the data you send. In that case, please enter your email address.